Architecture

Same computer. Two very different rooms.

In a hotel, the point of the heat is to be captured. In a locker, the point of the heat is to leave the parcels alone. The GPU is managed either way.

Principle · heat

Where the heat is made

A GPU is a heater that also computes. Electrical energy in, heat out, then a preheat loop. One kilowatt-hour at the chip is about one kilowatt-hour of heat. The meter, not the diagram, says what crossed the exchanger.

01

Power in

A metered circuit feeds the cabinet. What the meter records is what the GPU is allowed to draw.

02

GPU

The chip does the compute. Nearly all of that electricity leaves the silicon as heat. That is the source.

03

Cold plate

Liquid lifts the heat off the package. This loop stays on the IT side of the cabinet.

04

Exchanger

A double wall. Coolant and building water meet as temperatures, not as fluids.

05

Water and pool

Preheat for guest hot water, and the pool circuit where the plant can take it. Boilers still finish the setpoint.

Principle · compute

One training run, many rooms

A distributed AI server is not a new hall. A training job is split across nodes that already have an address — a hotel plant room, a locker bay — and the pieces come back as one run. Inference uses the same nodes between training jobs.

Training job

One run, sharded

Scheduler sends a shard out. Gradients and checkpoints return.

H1

Hotel plant

Shard A

L1

Street locker

Shard B

H2

Leisure hotel

Shard C

L1

Building locker

Shard D

Return path — the run stays one job. Parcel data, guest Wi-Fi, and payment networks are not on this path.

Revenue model

Zero cost to build. Server rental covers the expenditure.

The host does not fund construction. Arete builds the node, then rents the GPU. That rental is the income that carries the hardware, the power, and the service. The hotel receives heat and a report. It is not sold a share of the server.

  1. 01

    Host pays £0 to build

    No construction cost for the hotel or the locker operator. They provide the place: a plant room, or one bay.

  2. 02

    Arete funds the node

    Cabinet, GPU, exchanger or sealed bay, meter, and the connection. The hardware stays ours.

  3. 03

    The server is rented

    Training runs and inference are sold as managed GPU time. That rental is the income.

  4. 04

    Rent covers the cost

    Hardware, electricity, and service are carried by the server rental — not by a bill to the host for the build.

The site agreement sets the meter and the term. This is the structure — host build at no construction cost, server rental as the income — not a forecast for a building we have not surveyed.

Hotel and pool

Two loops that do not mix.

  1. IT coolant

    Cold plate on the GPU, a pump, and a closed loop inside the cabinet. Drip tray. Smoke and leak detection. Power isolation if either trips.

  2. Double-wall exchanger

    Coolant and building water meet only through the exchanger, double-wall where the design requires it.

  3. Building preheat

    Onward to the domestic hot-water preheat, and to the pool circuit on sites where that connection is real. Final temperature stays with existing plant. Legionella control stays with the hotel.

Hotel pilot details

Locker bay

One compartment, thermally finished.

  1. Sealed module

    The GPU lives in a closed bay with its own coolant. It is not an open card behind a parcel door.

  2. Heat rejection

    Heat leaves through that module’s own path. Neighbouring compartments stay at locker ambient. Parcels are not a radiator.

  3. Optional building couple

    If a locker already sits against a plant room — some hotels have both — the survey can ask whether heat can be coupled. Street cabinets are designed to reject heat, not to warm a pavement.

Locker node details

Controls on every node

Metered power

A dedicated circuit, a local isolator, and a meter. The number in the report is a measurement.

Remote management

BMC, signed updates, disk encryption, secure boot. The cabinet is locked. Tamper raises an alert.

Fail quiet

If cooling, leak detection, or the building side is unhappy, compute stops. The hotel’s water does not.

No guest path

Segregated network. Not guest Wi-Fi, not the property system, not payments, not parcel data.